Jaspertronics™ 80W 254nm Germicidal High Bay UV-C Tube Light Fixture with Dual Lamps, Remote, & Safety Sensors

6 In Stock! Same Day Shipping Through 3PM CST! Need more? Call today @ 888.391.5596
  • $ 149.99
  • Save $ 50.00




The 80W Germicidal UV-C 254nm Linear High Bay Tube Light offers advanced ultraviolet purification, effectively disinfecting enclosed spaces like schools, restaurants, and offices. Base G5. Mounted on the ceiling, it purifies 4.57 square meters in just 1 minute, eliminating 99.9% of bacteria. Equipped with a remote control, 18-second delay start-up, and built-in microwave and PIR sensors, it ensures safety and efficiency. Its mirror aluminum design enhances purification intensity, while high-strength steel provides protection. Certified by CE, RoHS, FCC, ETL, FDA, and EPA, it's a reliable choice for high-efficacy purification.


Applications
  • Office Buildings
  • Schools / Universities
  • Day Care Centers
  • Churches
  • Hospital / Health Care Facilities
  • Supermarkets / Retail Environments
  • Residential / Hotels
  • Restaurants / Entertainment Centers
  • Laboratory / Research Facility
  • Powerful UV-C Purification: Experience high-efficacy purification with our 80W UV-C 254nm tube light, designed for comprehensive disinfection. Mounted on ceilings, it effectively purifies enclosed spaces in schools, restaurants, supermarkets, offices, and public areas, eliminating 99.9% of bacteria within a 1-meter radius in just 1 minute.
  • Advanced Safety Features: Equipped with a remote control that includes an 18-second delay start-up, our UV-C light prioritizes safety. The built-in microwave sensor and PIR sensor ensure that the light only operates when the space is unoccupied, providing peace of mind for users.
  • Enhanced Purification Intensity: The mirror aluminum construction enhances ultraviolet purification intensity, ensuring thorough and efficient disinfection. This design maximizes the light's effectiveness, making it a reliable choice for maintaining a clean and safe environment.
  • Durable and Certified Design: Constructed with high-strength steel protection, our UV-C light is built to last. It comes with CE, RoHS, FCC, ETL, FDA, and EPA certifications, as well as SGS purification test reports, guaranteeing a product that meets rigorous safety and quality standards.
  • Versatile Application: Perfect for various settings, this UV-C purification tube light is ideal for use in educational institutions, dining establishments, retail environments, and more. Its integrated intelligent ultraviolet technology ensures comprehensive coverage and effective purification across multiple spaces.
Germicidal UV-C 254nm Linear High Bay Tube Light

Lamp Specifications

Specifications Data
Product Code U12-80W-01
Lamp Type UVC
Lamp Base G5
Color Matt Silver
Wave length 254 nm
Operating Temperature -10~35 °C
Dimensions 1313mm * 67mm * 54mm
Life span 9000 H
Warranty 1 Year Warranty

Features:

  • Quartz Tube
  • Wireless Remote
  • 20s delay start-up
  • Ozone-free UV
  • Microwave and PIR Sensor Built-in
  • Effectively kill 99.99% mites
  • Effectively kill parasites
  • Effectively kill virus
  • UV Irradiation

Wireless Remote:

Wireless remote helps to operate at a safe distance, ensuring that you can properly follow all UVC usage safety precautions.

Built-in Microwave + PIR Sensor:

The built in sensors will shut down the device when it senses human activity for added safety support, resuming operation when the space is clear.

FAQ

1. What is the coverage area of the high bay if hung from the ceiling 8.2 Feet (2.5 meters) from ground?------ It is (L)14.5 feet x (W)11.12 feet ( (L)4.46m x (W)3.39m )

2. I assume, as it is rectangular, the coverage will be the same. But what coverage area will get sufficient dosage?----- the distance between two UVC high bays should be less than 11.5 feet (3.43m) to maintain proper dosage to all areas of the space.

3. What is the minimum distance they should be from each other for proper operation? The distance between two UVC high bays should be less than 11.5 feet (3.43m) to maintain proper dosage to all areas of the space. As you know the microwave sensor have an effect on each other,so the min. distance for each two UVC high bay fixtures have to be over 0.5 meters. From the below Ultraviolet radiation intensity of our GKU12-80W-01 UVC high bay fixture,we can see the radiation from 3 meters is getting weak, our suggestion minimum distance from each other is around 2 meters.

Shipping Policy

Ask a Question

THE U12-80W-01 IS CENTRALLY LOCATED & SHIPPING FROM MISSOURI, USA!
American Flag

While we are working to ensure each image we have posted is accurate, there may be items with an incorrect or missing image. Please be sure you are ordering the correct model.

If you have any questions about the U12-80W-01 do not hesitate to contact via email at products@jaspertronics.com or by phone at 888-391-5596
Buy Smart, Buy Bright, Buy Jaspertronics!



We Also Recommend

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question
American Flag CENTRALLY LOCATED SHIPPING FROM MISSOURI, USA! American Flag